APC Smart-UPS
Part# SMT3000RMI2U
EAN:0731304284642
APC Smart-UPS 3000 LCD - UPS (rack-mountable) - AC 220/230/240 V - 2.7 kW - 3000 VA - RS-232, USB - output connectors: 9 - 2U - for P/N: AR3003, AR3003SP, AR3006, AR3006SP, AR3103, AR3103SP, AR3106, AR3106SP, AR3357X674
Native product specifications. The product description originates from Cnet. Foxway Distribution accepts no responsibility for error or misinformation in product descriptions from Cnet.
Product specifications
Product Description | APC Smart-UPS 3000 LCD - UPS - 2.7 kW - 3000 VA |
Manufacturer Warranty | 3-year warranty |
Dimensions (WxDxH) | 48 cm x 68.3 cm x 8.6 cm |
Weight | 44.3 kg |
Networking | RS-232, USB |
Device Type | UPS - rack-mountable |
Battery | Lead Acid |
Input Voltage | AC 220/230/240 V |
Output Voltage | AC 220/230/240 V |
Rack Size | 2U |
Run Time (Up To) | 3.2 min at full load |
Power Capacity | 2.7 kW / 3000 VA |
Designed For | P/N: AR3003, AR3003SP, AR3006, AR3006SP, AR3103, AR3103SP, AR3106, AR3106SP, AR3140G, AR3155W, AR3305W, AR3340G, AR3355W, AR3357X674, AR4018IX429, AR4018SP, AR4018SPX429, AR4018SPX431, AR4018SPX432, AR4018X429, AR4024IX431, AR4024SP, AR4024SPX429, AR4024SPX431, AR4024SPX432, AR4038IX432, NBWL0356A |
Input Connectors | Power IEC 60320 C20, power CEE 7/7, power BS 1363A |
Output connectors | 8 x power IEC 60320 C13 ¦ 1 x power IEC 60320 C19 |
Ogólne cechy
Device Type | UPS - rack-mountable |
Height (Rack Units) | 2U |
Porty
Interfaces | 1 x USB ¦ 1 x serial |
Expansion Slots | 1 (total) / 1 (free) x SmartSlot |
Warranty
Service & Support | Limited warranty - 3 years ¦ Limited warranty - batteries - 2 years |
Network
Remote Management Interface | RS-232, USB |
Compliance
Cables Included | Serial cable ¦ USB cable ¦ Power cable - integrated - 2 m |
Rack Mounting Kit | Included |
Features | Audible alarm, LCD display, Automatic Voltage Regulation (AVR), LED indicators |
Compliant Standards | C-Tick, GOST, EN 60950, GS, VDE, IEC 62040-1-1, RoHS Exemption 7b, IEC 62040-2, IRAM, WEEE, REACH |
Oprogramowanie
Software Included | Drivers & Utilities |
HDD / SSD tolerance
Min Operating Temperature | 0 °C |
Max Operating Temperature | 40 °C |
Humidity Range Operating | 0 - 95% |
Sound Emission | 55 dBA |
Bateria
Technology | Lead Acid |
Run Time (Up To) | 3.2 min at full load ¦ 11.5 min at half load |
Recharge Time | 3 hours |
Pojemność
UPS Technology | Line interactive |
Input Voltage | AC 220/230/240 V |
Input Voltage Range | AC 160 - 286 V |
Input Voltage Range (Adjustable) | AC 151 - 299 V |
Frequency Required | 50/60 Hz |
Input Connectors | Power IEC 60320 C20, power CEE 7/7, power BS 1363A |
Power Output Connectors Details | 8 x power IEC 60320 C13 ¦ 1 x power IEC 60320 C19 |
Output Voltage | AC 220/230/240 V |
Power Capacity | 2.7 kW / 3000 VA |
Output Waveform | Sinewave |
Surge Suppression | Yes |
Surge Energy Rating | 320 Joules |
Circuit Protection | Circuit breaker |
Wymiary
Width | 48 cm |
Depth | 68.3 cm |
Height | 8.6 cm |
Weight | 44.3 kg |
Wymiary wysyłki
Shipping Width | 60 cm |
Shipping Depth | 98 cm |
Shipping Height | 25.4 cm |
Shipping Weight | 51.7 kg |
Kompatybilne z
Designed For | P/N: ACCS1000, ACCS1001, ACCS1002, ACCS1003, ACCS1004, ACCS1005, ACCS1006, ACCS1007, ACDC1015, ACDC1016, ACDC1017, ACDC1019, ACDC1020, ACDC1021, ACDC2513, ACF001, ACF002, ACF003, ACF101BLK, ACF102BLK, ACF201BLK, ACF400, AP5017, AP5602, AP5606, AP5607, AP5616, AP92200, AP9290, AR202, AR203A, AR204A, AR2101, AR2102BLK, AR2144BLK, AR2145BLK, AR2200, AR2280, AR2400, AR2400FP1, AR2401, AR2407, AR2480, AR2487, AR2487G, AR2500, AR2507, AR2580, AR2587, AR2900, AR2901, AR3000, AR3003, AR3003SP, AR3006, AR3006SP, AR3100, AR3100G, AR3100SP, AR3100SP1, AR3100SP2, AR3100TAA, AR3100W, AR3100X609, AR3100X610, AR3100X617, AR3101, AR3103, AR3103SP, AR3104, AR3104SP1, AR3105, AR3105SP, AR3105W, AR3106, AR3106SP, AR3107, AR3107G, AR3107SP, AR3107X609, AR3107X610, AR3107X617, AR3130, AR3140, AR3140G, AR3140W, AR3150, AR3150SP, AR3150SP1, AR3150SP2, AR3150W, AR3150X609, AR3150X610, AR3150X617, AR3155, AR3155SP, AR3155W, AR3157, AR3157SP, AR3157X609, AR3157X610, AR3157X617, AR3200, AR3300, AR3300G, AR3300SP, AR3300W, AR3300X609, AR3300X610, AR3300X617, AR3305, AR3305SP, AR3305W, AR3307, AR3307SP, AR3307W, AR3307X609, AR3307X610, AR3307X617, AR3340, AR3340G, AR3340W, AR3347, AR3350, AR3350SP, AR3350W, AR3350X609, AR3350X610, AR3350X617, AR3355, AR3355SP, AR3355W, AR3357, AR3357SP, AR3357X609, AR3357X610, AR3357X617, AR3357X674, AR4018, AR4018A, AR4018I, AR4018IA, AR4018IX429, AR4018IX431, AR4018IX432, AR4018SP, AR4018SPX429, AR4018SPX431, AR4018SPX432, AR4018X429, AR4018X431, AR4018X432, AR4024, AR4024A, AR4024I, AR4024IA, AR4024IX429, AR4024IX431, AR4024IX432, AR4024SP, AR4024SPX429, AR4024SPX431, AR4024SPX432, AR4024X429, AR4024X431, AR4024X432, AR4038, AR4038A, AR4038I, AR4038IA, AR4038IX429, AR4038IX431, AR4038IX432, AR4038X429, AR4038X431, AR4038X432, AR7007, AR7050, AR7057, AR8135BLK, NBWL0356A |
Specifications
Intelligent and efficient network power protection from entry level to scalable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.
- Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. - Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. - Audible alarms
Provides notification of changing utility power and UPS power conditions - Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power. - Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced. - Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance - Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models). - Cold-start capable
Provides temporary battery power when the utility power is out. - Disconnected battery notification
Warns when a battery is not available to provide backup power. - Energy meter
Provides actual kilowatt hours of usage for energy conscious users. - Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. - Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection. - High online efficiency
Reduces utility costs, generates less heat. - Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced - Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging. - Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys. - LED Indicators
Provide easy-to-read status of the unit and utility power conditions. - Network manageable
Most models provide remote power management options of the UPS over the network. Many do not have NMC embedded. - Outlet group control
Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups). - Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement. - Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning. - Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics. - Safety-agency approved
The UPS is UL1778 Listed - Sequenced network shutdown and reboot
Customize network shutdown and reboot sequence of connected servers and UPSs. - Serial connectivity
Provides management of the UPS via a serial port. - Single switched outlet group
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding. - StruxureWare Data Center Expert compatible
Enables centralized management via StruxureWare Data Center Expert. - Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature. - USB connectivity
Provides management of the UPS via a USB port (not available on all models). - User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) - Wide input voltage range
Designed for harsh electrical environments to save battery life.